ITEMS INCLUDED:
- Permits and fees, one year functional warranty, ten year limited Bonded Builder Home Warranty, survey, insurance, construction financing, plans, specifications,
construction supervision, and five hours with interior designer.
FOUNDATION:
- Post Tension monolithic slab engineered per site (10’ x 28’ support beams – minimum)
- 4” cushion of sand under 4” of 3,000 P.S.I. Concrete.
- 6 mil polyethylene moisture barrier.
FRAMING:
- Generally accepted industry practices governed by City of Carrollton Building Codes.
- Minimum 2” x 4” kin dried finger jointed studs on all framed walls, 16” on center.
- Roof Deck material is 7/16 OSB, energy board
EXTERIOR WALLS, ECT:
- Sheathing: Thermoply
- Siding and Fascia – Cement Fiber Board.
- Soffits – Perforated Cement Fiber Board.
- Cast Stone accents per plan
- Rock – per plan – Allowance $140/ton
- Brick: King size – Clay, kiln-dried - $320/M
- Mortar: Buff
- Stucco elevations – Hard cement stucco, decorations per plan of Styrofoam.
EXTERIOR DOORS
- Front Door – Wood or metal ($2,000 per door)
- Other Exterior Doors; Per Plan fiberglass
WINDOWS:
- Type-Aluminum with insulated, double pane low E glass
- Glass – 1/1 on rear and side elevation
- Screens on all windows that open
GARAGE DOORS AND INTERIOR WALLS:
- Size per Plan; Metal – No windows.
- Garage door opner remote controls for each door.
- Pained garage floors
- Garage walls and ceilings will be tetured, painted, trimmed and base molding.
FIREPLACE PER PLAN:
- Metal, gas log (non-wood burning) with gas starter
- Facing: Stone or Stonecraft to 4'
- Hearth: Raised - Stone or Stonecraft
- Chimney - None
- Chimney cap - None
- Mantle - Stone or Stonecraft
ROOFING
- Type – Composition – Malarkey 50 year
- Color – Customer will select
- Air Hawks Roof Vent
- Weight – 300#
GUTTERS AND DOWNSPOUTS:
- Full Gutters
- Type – Aluminum – 4” O Gee; 4” O Gee downspouts